This page is part of archived documentation for openHAB 3.0. Go to the current stable version
# Fronius Binding
This binding uses the Fronius Solar API V1 (opens new window) to obtain data from a Fronius devices.
# Supported Things
Support Fronius Galvo, Fronius Symo inverters and other Fronius inverters in combination with the Fronius Datamanager 1.0 / 2.0 or Fronius Datalogger. You can add multiple inverters that depend on the same datalogger with different device ids. (Default 1)
# Discovery
There is no discovery implemented. You have to create your things manually and specify the hostname or IP address of the Datalogger and the device id.
# Binding Configuration
The binding has no configuration options, all configuration is done at bridge
or powerinverter
level.
# Thing Configuration
# Bridge Thing Configuration
Parameter | Description |
---|---|
hostname | The hostname or IP address of your Fronius Datalogger |
refreshInterval | Refresh interval in seconds |
# Powerinverter Thing Configuration
Parameter | Description |
---|---|
deviceId | The identifier of your device (Default: 1) |
# Channels
Channel ID | Item Type | Description |
---|---|---|
inverterdatachanneldayenergy | Number | Energy generated on current day |
inverterdatachannelpac | Number | AC powery |
inverterdatachanneltotal | Number | Energy generated overall |
inverterdatachannelyear | Number | Energy generated in current year |
inverterdatachannelfac | Number | AC frequency |
inverterdatachanneliac | Number | AC current |
inverterdatachannelidc | Number | DC current |
inverterdatachanneluac | Number | AC voltage |
inverterdatachanneludc | Number | DC voltage |
inverterdatadevicestatuserrorcode | Number | Device error code |
inverterdatadevicestatusstatuscode | Number | Device status code0 - 6 Startup7 Running 8 Standby9 Bootloading10 Error |
powerflowchannelpgrid | Number | Power + from grid, - to grid |
powerflowchannelpload | Number | Power + generator, - consumer |
powerflowchannelpakku | Number | Power + charge, - discharge |
# Full Example
demo.things:
Bridge fronius:bridge:mybridge [hostname="192.168.66.148", refreshInterval=5] {
Thing powerinverter myinverter [deviceId=1]
}
demo.items:
Number AC_Powery { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelpac" }
Number Day_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneldayenergy" }
Number Total_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneltotal" }
Number Year_Energy { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelyear" }
Number FAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelfac" }
Number IAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneliac" }
Number IDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachannelidc" }
Number UAC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneluac" }
Number UDC { channel="fronius:powerinverter:mybridge:myinverter:inverterdatachanneludc" }
Number ErrorCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatuserrorcode" }
Number StatusCode { channel="fronius:powerinverter:mybridge:myinverter:inverterdatadevicestatusstatuscode" }
Number Grid_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpgrid" }
Number Load_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpload" }
Number Battery_Power { channel="fronius:powerinverter:mybridge:myinverter:powerflowchannelpakku" }
Tested with a Fronius Symo 8.2-3-M