# Daikin Binding
The Daikin binding allows you to control your Daikin air conditioning units with openHAB. In order to do so, your Daikin air conditioning unit must have a BRP072A42, BRP072C42 or BRP15B61 WiFi adapter installed.
# Supported Things
Daikin air conditioning units with a BRP069B41, BRP072A42, BRP072C42 or BRP15B61 installed. This may work with the older KRP series of wired adapters, but has not been tested with them.
# Discovery
This add-on will broadcast messages on your local network looking for Daikin air conditioning units and adding them to the queue of new items discovered. You can also manually add a new item if you know the IP address.
# BRP072C42 adapter discovery
A BRP072C42 adapter requires a registered UUID to authenticate. Upon discovery, a UUID will be generated but the adapter's key must be entered in the Thing configuration to complete the UUID registration.
# Thing Configuration
host
- The hostname of the Daikin air conditioner. Typically you'd use an IP address such as192.168.0.5
for this field.refresh
- The frequency with which to refresh information from the Daikin air conditioner specified in seconds. Defaults to 60 seconds.
# Additional Thing configurations for BRP072C42 adapter
secure
- Must be set to true for BRP072C42 to access it through https.uuid
- A UUID used to access the BRP072C42 adapter. A handy UUID generator can be found at https://www.uuidgenerator.net/ (opens new window).key
- The 13-digit key from the Daikin adapter.
# Channels
The temperature channels have a precision of one half degree Celsius. For the BRP072A42 and BRP072C42:
Channel Name | Description |
---|---|
power | Turns the power on/off for the air conditioning unit. |
settemp | The temperature set for the air conditioning unit. |
indoortemp | The indoor temperature as measured by the unit. |
outdoortemp | The outdoor temperature as measured by the external part of the air conditioning system. May not be available when unit is off. |
humidity | The indoor humidity as measured by the unit. This is not available on all units. |
mode | The mode set for the unit (AUTO, DEHUMIDIFIER, COLD, HEAT, FAN) |
homekitmode | A mode that is compatible with homekit/alexa/google home (off, auto, heat, cool). Not tested for BRP069B41 |
fanspeed | The fan speed set for the unit (AUTO, SILENCE, LEVEL_1, LEVEL_2, LEVEL_3, LEVEL_4, LEVEL_5) |
fandir | The fan blade direction (STOPPED, VERTICAL, HORIZONTAL, VERTICAL_AND_HORIZONTAL) |
cmpfrequency | The compressor frequency |
specialmode | The special mode currently active (OFF, STREAMER, ECO, POWERFUL, POWERFUL & STREAMER, ECO & STREAMER). Not all modes might be available on the unit. |
specialmode-powerful | Turns the powerful mode on/off for the air conditioning unit. |
energyheatingcurrentyear-1 | The energy consumption when heating for current year January |
energyheatingcurrentyear-2 | The energy consumption when heating for current year February |
energyheatingcurrentyear-3 | The energy consumption when heating for current year March |
energyheatingcurrentyear-4 | The energy consumption when heating for current year April |
energyheatingcurrentyear-5 | The energy consumption when heating for current year May |
energyheatingcurrentyear-6 | The energy consumption when heating for current year June |
energyheatingcurrentyear-7 | The energy consumption when heating for current year July |
energyheatingcurrentyear-8 | The energy consumption when heating for current year August |
energyheatingcurrentyear-9 | The energy consumption when heating for current year September |
energyheatingcurrentyear-10 | The energy consumption when heating for current year October |
energyheatingcurrentyear-11 | The energy consumption when heating for current year November |
energyheatingcurrentyear-12 | The energy consumption when heating for current year December |
energycoolingcurrentyear-1 | The energy consumption when cooling for current year January |
energycoolingcurrentyear-2 | The energy consumption when cooling for current year February |
energycoolingcurrentyear-3 | The energy consumption when cooling for current year March |
energycoolingcurrentyear-4 | The energy consumption when cooling for current year April |
energycoolingcurrentyear-5 | The energy consumption when cooling for current year May |
energycoolingcurrentyear-6 | The energy consumption when cooling for current year June |
energycoolingcurrentyear-7 | The energy consumption when cooling for current year July |
energycoolingcurrentyear-8 | The energy consumption when cooling for current year August |
energycoolingcurrentyear-9 | The energy consumption when cooling for current year September |
energycoolingcurrentyear-10 | The energy consumption when cooling for current year October |
energycoolingcurrentyear-11 | The energy consumption when cooling for current year November |
energycoolingcurrentyear-12 | The energy consumption when cooling for current year December |
For the BRP15B61:
Channel Name | Description |
---|---|
power | Turns the power on/off for the air conditioning unit. |
settemp | The temperature set for the air conditioning unit. |
indoortemp | The indoor temperature as measured by the unit. |
outdoortemp | The outdoor temperature as measured by the external part of the air conditioning system. May not be available when unit is off. |
mode | The mode set for the unit (AUTO, DEHUMIDIFIER, COLD, HEAT, FAN) |
homekitmode | A mode that is compatible with homekit/alexa/google home (off, auto, heat, cool) |
airbasefanspeed | The fan speed set for the unit (AUTO, AIRSIDE, LEVEL_1, LEVEL_2, LEVEL_3, LEVEL_4, LEVEL_5, AUTO_LEVEL_1, AUTO_LEVEL_2, AUTO_LEVEL_3, AUTO_LEVEL_4, AUTO_LEVEL_5) |
zone1 | Turns zone 1 on/off for the air conditioning unit (if a zone controller is installed.) |
zone2 | Turns zone 2 on/off for the air conditioning unit. |
zone3 | Turns zone 3 on/off for the air conditioning unit. |
zone4 | Turns zone 4 on/off for the air conditioning unit. |
zone5 | Turns zone 5 on/off for the air conditioning unit. |
zone6 | Turns zone 6 on/off for the air conditioning unit. |
zone7 | Turns zone 7 on/off for the air conditioning unit. |
zone8 | Turns zone 8 on/off for the air conditioning unit. |
# Full Example
daikin.things:
// for BRP069B41 or BRP072A42
daikin:ac_unit:living_room_ac [ host="192.168.0.5" ]
// for BRP072C42
daikin:ac_unit:living_room_ac [ host="192.168.0.5", secure=true, uuid="xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx", key="xxxxxxxxxxxxx" ]
// for Airbase (BRP15B61)
daikin:airbase_ac_unit:living_room_ac [ host="192.168.0.5" ]
daikin.items:
// for BRP069B41, BRP072A42 or BRP072C42
Switch DaikinACUnit_Power { channel="daikin:ac_unit:living_room_ac:power" }
Number:Temperature DaikinACUnit_SetPoint { channel="daikin:ac_unit:living_room_ac:settemp" }
String DaikinACUnit_Mode { channel="daikin:ac_unit:living_room_ac:mode" }
String DaikinACUnit_HomekitMode { channel="daikin:ac_unit:living_room_ac:homekitmode" }
String DaikinACUnit_Fan { channel="daikin:ac_unit:living_room_ac:fanspeed" }
String DaikinACUnit_Fan_Movement { channel="daikin:ac_unit:living_room_ac:fandir" }
Number:Temperature DaikinACUnit_IndoorTemperature { channel="daikin:ac_unit:living_room_ac:indoortemp" }
Number:Temperature DaikinACUnit_OutdoorTemperature { channel="daikin:ac_unit:living_room_ac:outdoortemp" }
// for Airbase (BRP15B61)
Switch DaikinACUnit_Power { channel="daikin:airbase_ac_unit:living_room_ac:power" }
Number:Temperature DaikinACUnit_SetPoint { channel="daikin:airbase_ac_unit:living_room_ac:settemp" }
String DaikinACUnit_Mode { channel="daikin:airbase_ac_unit:living_room_ac:mode" }
String DaikinACUnit_HomekitMode { channel="daikin:airbase_ac_unit:living_room_ac:homekitmode" }
String DaikinACUnit_Fan { channel="daikin:airbase_ac_unit:living_room_ac:fanspeed" }
Number:Temperature DaikinACUnit_IndoorTemperature { channel="daikin:airbase_ac_unit:living_room_ac:indoortemp" }
Number:Temperature DaikinACUnit_OutdoorTemperature { channel="daikin:airbase_ac_unit:living_room_ac:outdoortemp" }
Switch DaikinACUnit_Zone1 { channel="daikin:airbase_ac_unit:living_room_ac:zone1" }
Switch DaikinACUnit_Zone2 { channel="daikin:airbase_ac_unit:living_room_ac:zone2" }
Switch DaikinACUnit_Zone3 { channel="daikin:airbase_ac_unit:living_room_ac:zone3" }
Switch DaikinACUnit_Zone4 { channel="daikin:airbase_ac_unit:living_room_ac:zone4" }
Switch DaikinACUnit_Zone5 { channel="daikin:airbase_ac_unit:living_room_ac:zone5" }
Switch DaikinACUnit_Zone6 { channel="daikin:airbase_ac_unit:living_room_ac:zone6" }
Switch DaikinACUnit_Zone7 { channel="daikin:airbase_ac_unit:living_room_ac:zone7" }
Switch DaikinACUnit_Zone8 { channel="daikin:airbase_ac_unit:living_room_ac:zone8" }
daikin.sitemap:
// for BRP069B41, BRP072A42 or BRP072C42
Switch item=DaikinACUnit_Power
Setpoint item=DaikinACUnit_SetPoint visibility=[DaikinACUnit_Power==ON]
Selection item=DaikinACUnit_Mode mappings=["AUTO"="Auto", "DEHUMIDIFIER"="Dehumidifier", "COLD"="Cold", "HEAT"="Heat", "FAN"="Fan"] visibility=[DaikinACUnit_Power==ON]
Selection item=DaikinACUnit_Fan mappings=["AUTO"="Auto", "SILENCE"="Silence", "LEVEL_1"="Level 1", "LEVEL_2"="Level 2", "LEVEL_3"="Level 3", "LEVEL_4"="Level 4", "LEVEL_5"="Level 5"] visibility=[DaikinACUnit_Power==ON]
Selection item=DaikinACUnit_Fan_Movement mappings=["STOPPED"="Stopped", "VERTICAL"="Vertical", "HORIZONTAL"="Horizontal", "VERTICAL_AND_HORIZONTAL"="Vertical and Horizontal"] visibility=[DaikinACUnit_Power==ON]
Text item=DaikinACUnit_IndoorTemperature
Text item=DaikinACUnit_OutdoorTemperature
// for Airbase (BRP15B61)
Switch item=DaikinACUnit_Power
Setpoint item=DaikinACUnit_SetPoint visibility=[DaikinACUnit_Power==ON]
Selection item=DaikinACUnit_Mode mappings=["AUTO"="Auto", "DEHUMIDIFIER"="Dehumidifier", "COLD"="Cold", "HEAT"="Heat", "FAN"="Fan"] visibility=[DaikinACUnit_Power==ON]
Selection item=DaikinACUnit_Fan visibility=[DaikinACUnit_Power==ON]
Text item=DaikinACUnit_IndoorTemperature
Text item=DaikinACUnit_OutdoorTemperature
Switch item=DaikinACUnit_Zone1 visibility=[DaikinACUnit_Power==ON]
Switch item=DaikinACUnit_Zone2 visibility=[DaikinACUnit_Power==ON]
Switch item=DaikinACUnit_Zone3 visibility=[DaikinACUnit_Power==ON]
Switch item=DaikinACUnit_Zone4 visibility=[DaikinACUnit_Power==ON]
Switch item=DaikinACUnit_Zone5 visibility=[DaikinACUnit_Power==ON]
Switch item=DaikinACUnit_Zone6 visibility=[DaikinACUnit_Power==ON]
Switch item=DaikinACUnit_Zone7 visibility=[DaikinACUnit_Power==ON]
Switch item=DaikinACUnit_Zone8 visibility=[DaikinACUnit_Power==ON]